Incident update

1. Record alarms before resetting

Open the message window using the yellow alarm icon. Photograph all rows and record each alarm number, full text, date and time. Do not press RESET/ACK or start another cycle yet. Time order helps distinguish the first alarm from stopping consequences. Manual illustrations are examples, not alarms observed in this case.

2. Read the wrapping step and mode

On the automatic-mode screen, record the current step number and description in field D, program in field C and header states: Manual/Automatic, Pause/Running and EM1 OK/NOK. Do not switch anything. Step and mode distinguish waiting for a prior condition from unwinding failure; the prestretch command also depends on sequence and operating states.

3. Add roll indication and ASi status

Using the key icon, open Miscellaneous → Home position and photograph the roll-loaded indication, homing and overall home-position state. Do not activate a return movement; its step is not the wrapping step. Then open ASi bus and record network and 16A/16B participant states, including the legend. Do not change addresses. An ASi fault points to communication, while a healthy state confirms neither sensor function nor roll movement.

Evidence and missing information

Evidence gaps (3)

  • The exact alarm, wrapping step and actual HMI states have not been read; the cause is unconfirmed.
  • Roll and roller movement, the sensor and wiring have not been checked. A static HMI reading does not establish mechanical function.
  • HMI sources do not establish that individual I94B2/I94B3 pulses are displayed; ASi diagnostics does not replace functional verification.