ifab1_BACKUP_2012-05-29
Context for Edmund
Edit detailsiFAB1 controller backup with RobotWare 5.14.0204.00 for the ABB IRB 2600. Configured for arc welding with the Arc option and Miller welding power-source extension. Also includes DeviceNet communication, multitasking, work zones, path recovery and collision detection. https://github.com/mikedh/ifab_archive/tree/master
iFAB1 – ABB IRB 2600-12/1.85 robotic welding cell
Robotic cell with an ABB IRB 2600-12/1.85 Type A manipulator configured for arc welding. The controller includes Arc, the AW-MILLER-AA-007 welding power source extension and BullsEye.
RAPID modules
LINKEDM
Scope
Groups overlap — a signal can appear in more than one.
Signals
| Signal | Type | Device · address |
|---|---|---|
aiGasFlow | AI | — |
aiWireSpeed | AI | — |
aiWldCurrent | AI | — |
aiWldVoltage | AI | — |
aoReamerSpeed | AO | — |
aoWfsCmd | AO | — |
aoWldVoltCmd | AO | — |
diBullsEyeBeam | DI | — |
diFx1Clamp1Closed | DI | — |
diFx1Clamp1Open | DI | — |
diFx1Clamp2Closed | DI | — |
diFx1Clamp2Open | DI | — |
diFx1Clamp3Closed | DI | — |
diFx1Clamp3Open | DI | — |
diFx1PartPresent DrivesdoFx1Light | DI | — |
diFx1PinsDown | DI | — |
diFx1PinsUp | DI | — |
diFx1Spare1 | DI | — |
diFx1Spare2 | DI | — |
diGunClnDone | DI | — |
diGunClnHome | DI | — |
diGunInPosition | DI | — |
diPlcAckFault | DI | — |
diPlcBypassWeld | DI | — |
diPlcCycleStart | DI | — |
diPlcDryRun | DI | — |
diPlcGunServiceReq | DI | — |
diPlcHeartbeat | DI | — |
diPlcHomeReq | DI | — |
diPlcMotorOn | DI | — |
diPlcPartReady | DI | — |
diPlcResetErr | DI | — |
diPlcStart | DI | — |
diPlcStartMain | DI | — |
diPlcStop | DI | — |
diSfAreaScannerOk | DI | — |
diSfDoorClosed DrivessfCellSafe | DI | — |
diSfDoorLocked | DI | — |
diSfEStopChainOk DrivessfCellSafe | DI | — |
diSfLightCurtainOk DrivessfCellSafe | DI | — |
diSfMutingActive | DI | — |
diSfOpZoneClear | DI | — |
diSprayLevelOk | DI | — |
diTblLocked DrivessimPartOk | DI | — |
diTblMoving | DI | — |
diTblPosA | DI | — |
diTblPosB | DI | — |
diWireCutDone | DI | — |
diWld1ArcEst | DI | — |
diWld1ErrActive DrivesdoRobFault | DI | — |
Signal detail
aiGasFlow
- Device
- No device assigned
- Address
- —
- Connections
- No system mapping or cross connection
This signal is not assigned to a device, so it occupies no channels.
- AInputline 462
SERVER · main
- AInputline 86
WELDCELL · weldSample
- AInputline 87
WELDCELL · weldSample
Verze
- Version 1In useReady
RobotWare 5.14.0204.00 · Oct 23, 2026