ifab1_BACKUP_2012-05-29

ABB
IRC5
Ready
Latest version uploadedOct 23, 2026, 2:43:22 PMv1 · 5.14.0204.00 · ifab1

Context for Edmund

Edit details
Popis programu

iFAB1 controller backup with RobotWare 5.14.0204.00 for the ABB IRB 2600. Configured for arc welding with the Arc option and Miller welding power-source extension. Also includes DeviceNet communication, multitasking, work zones, path recovery and collision detection. https://github.com/mikedh/ifab_archive/tree/master

Popis stroje

iFAB1 – ABB IRB 2600-12/1.85 robotic welding cell

Robotic cell with an ABB IRB 2600-12/1.85 Type A manipulator configured for arc welding. The controller includes Arc, the AW-MILLER-AA-007 welding power source extension and BullsEye.

RAPID modules

16 modules
ROB_1ROB1_2600_1.85_12
ROBOT_LI600ROBOT_TYPE_LI600

LINKEDM

System module
—End of module · 55 lines

Scope

Groups overlap — a signal can appear in more than one.

Signals

SignalTypeDevice · address
aiGasFlow
AI
—
aiWireSpeed
AI
—
aiWldCurrent
AI
—
aiWldVoltage
AI
—
aoReamerSpeed
AO
—
aoWfsCmd
AO
—
aoWldVoltCmd
AO
—
diBullsEyeBeam
DI
—
diFx1Clamp1Closed
DI
—
diFx1Clamp1Open
DI
—
diFx1Clamp2Closed
DI
—
diFx1Clamp2Open
DI
—
diFx1Clamp3Closed
DI
—
diFx1Clamp3Open
DI
—
diFx1PartPresent
DrivesdoFx1Light
DI
—
diFx1PinsDown
DI
—
diFx1PinsUp
DI
—
diFx1Spare1
DI
—
diFx1Spare2
DI
—
diGunClnDone
DI
—
diGunClnHome
DI
—
diGunInPosition
DI
—
diPlcAckFault
DI
—
diPlcBypassWeld
DI
—
diPlcCycleStart
DI
—
diPlcDryRun
DI
—
diPlcGunServiceReq
DI
—
diPlcHeartbeat
DI
—
diPlcHomeReq
DI
—
diPlcMotorOn
DI
—
diPlcPartReady
DI
—
diPlcResetErr
DI
—
diPlcStart
DI
—
diPlcStartMain
DI
—
diPlcStop
DI
—
diSfAreaScannerOk
DI
—
diSfDoorClosed
DrivessfCellSafe
DI
—
diSfDoorLocked
DI
—
diSfEStopChainOk
DrivessfCellSafe
DI
—
diSfLightCurtainOk
DrivessfCellSafe
DI
—
diSfMutingActive
DI
—
diSfOpZoneClear
DI
—
diSprayLevelOk
DI
—
diTblLocked
DrivessimPartOk
DI
—
diTblMoving
DI
—
diTblPosA
DI
—
diTblPosB
DI
—
diWireCutDone
DI
—
diWld1ArcEst
DI
—
diWld1ErrActive
DrivesdoRobFault
DI
—

Signal detail

aiGasFlow

AI
Input · Weld
Device
No device assigned
Address
—
Connections
No system mapping or cross connection
Channel map

This signal is not assigned to a device, so it occupies no channels.

Cross-references3 RAPID references
  • AInputline 462

    SERVER · main

  • AInputline 86

    WELDCELL · weldSample

  • AInputline 87

    WELDCELL · weldSample

Verze

1 version
  1. Version 1In use
    Ready

    RobotWare 5.14.0204.00 · Oct 23, 2026